System Works on Infrared Detection principle.
• The system is normally on standby position.
• When a user comes in front of the WC, the system
starts to count (red led) and waits for detection during
5 secs to be sure of the usage. If in this duration the
user leaves the system switches to standby position
again. If the user continues to use the WC then the
system accepts the usage (blue led). After this filter
period whenever the user leaves, the system waits
for 5 secs to be sure that the user has already left
and then flushes the water. The flushed water can be adjusted by the flushing time adjustment
switch on the backside of the electronic module. There is another switch on the backside of the
module for the adjustment of detection range.
Note: It must be used an independent water supply line/ pump for this system. The minimum
dynamic pressure required for a correct functioning is 3bar, and maximum 8 bar.
• Led indications:
Standby: no indication.
After first 5 secs. (filter time for usage), the blue led appears next to red led light.
(Optional Manual flush: Big flush activated by showing hand within 10cm in front of the IR sensor,
to clean the bowl).
Reduced flush volume: The user leaves the sensor range in less than 60 secs (4 secs flush).
Total flush volume: The user leaves the sensor range after 60 secs (8 secs. flush).
Led indications: Red light indicates that the system is in use. Blue light indicates that the system
has accepted the use.
> 5 s.
START
< 75 s.
~ 3 L
> 75 s.
~ 6 L
M
(preset ~70cm)
Z
(preset ~5 sec)
7

Publicidad

loading

Este manual también es adecuado para:

100104495