1. SPECIFICATIONS
1.1 Technical specifications
Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O
Average NO
concentration at 13% of O
x
Average OGC concentration at 13% of O
Particle concentration at 13% of O
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Flue duct
Ø Air inlet
Front safety distance
Side safety distance
Back safety distance
Base safety distance
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate No.:
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Flue liner connector.
2. Fireplace's body.
3. Flat string for the ceiling plate and flue liner connector.
4. Body of the ceiling plate.
5. Aluminium ring to connect.
6. Metal clamp.
7. Exterior air inlet cover.
8. Bag with screws.
9. Fixative of the aluminium ring.
10. Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
11. Bag with screws and anchors.
12. Heat-resistant spray paint for touch-ups.
13. Bag with washers and screws.
14. Upper baffle to limit the draught,
15. Tool for handling registers and opening door.
16. Heat-resistant glove
17. Cleaning cloth
18. Bag with metallic anchors
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Wall. Make sure the wall where the appliance will be placed is able to support the weight of the device. If not, you will need a load
spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2
2
2
2
Value
11-13 Pa
3 kg/h
7,66 g/s
89 %
10,5 kW
7 – 12,5 kW
0,10%
85,89 mg/Nm
68,77 mg/Nm
24,88 mg/Nm
13,6 Pa
128 kg
4 kg
200 mm
300 mm
4000 mm
180 mm
100 mm
1000 mm
200 mm
350 mm
410 mm
154º C
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20% - two years under cover
2019
19/18684-1039-1/2
Pag. 8
3
3
3