Indoor/Outdoor Unit Installation Drawings
The models adopt HFC free refrigerant R410A.
For installation of the indoor units,refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)
more than 15cm
more than
10cm
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
The marks from
to
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
The above indoor and outdoor units' picture is just for your reference.
Please be subject to the actual product purchased.
All manuals and user guides at all-guides.com
more than 10cm
more than 20cm
4
Compressor(Inside of Unit)
Attention must be paid to
the rising up of drain hose
G
F
A
C
more than
20cm
D
E
more than 25cm
AIR OUTLET
AIR INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
15
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.