Descargar Imprimir esta página

DeWalt DWFP12233 Manual De Instrucciones página 12

Clavadora de clavos pequeños de calibre 18

Publicidad

Idiomas disponibles

Idiomas disponibles

Cold Weather Operation
WARNING: Read the section titled Important Safety Instructions
at the beginning of this manual. Always wear eye and ear protection
when operating this tool. Keep the nailer pointed away from yourself
and others. For safe operation, complete the following procedures
and checks before each use of the nailer.
When operating tools at temperatures below freezing, complete
preparation procedures outlined above and follow the directions
below.
1. Make sure compressor tanks have been properly drained prior
to use. Always drain the compressor tanks at least once daily
while using the nailer. This is especially important in cold weather
because any moisture in the air in the tanks will condense in the
cold temperature.
2. Keep the tool as warm as possible prior to use.
3. Lower air pressure to 80 psi or less.
4. Actuate the tool 5 or 6 times into scrap lumber to lubricate o-rings.
5. Turn pressure up to operating level (not to exceed 120 psi) and
use tool as normal.
Hot Weather Operation
Tool should operate normally. However, keep tool out of direct sunlight
as excessive heat can damage bumpers, o-rings and other rubber
parts.
MAINTENANCE
WARNING: Disconnect air line from tool and remove fasteners
from magazine before making adjustments or personal injury may
result.
Clearing a Jammed Fastener (Fig. 7)
If a fastener becomes jammed in the nosepiece, keep the tool pointed
away from you and follow these instructions to clear:
1. Disconnect the tool from the air supply.
2. Open the magazine by depressing the magazine release button
and pulling open the magazine.
FIG. 7
3. Open the jam clearing nose door by pulling down and then up on
the latch.
4. Remove the jammed fastener. In certain circumstances, pliers
may be required to remove the fastener.
5. Perform tool operation check.
NOTE: Should fasteners continue to jam frequently in nosepiece,
have tool serviced by an authorized D
Daily Maintenance Chart
ACTION
Drain compressor tanks and hoses daily
WHY
Prevents accumulation of moisture in compressor and
nailer
HOW
Open petcocks or other drain valves on compressor
tanks. Allow any accumulated water to drain from
hoses