WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower (in the ceiling only)
when connected to a GFCI (Ground Fault Circuit Interrupter) -
protected branch circuit.
8. This unit must be grounded.
Typical Installation
• Attaches to 2" x 4" or greater
wall studs or ceiling joists.
Joists
I-Joists
The ducting from this fan to the outside
of the building has a strong effect on the
air flow, noise and energy use of the fan.
Use the shortest, straighest duct routing
possible for best performance, and avoid
installing the fan with smaller ducts than
recommended. Insulation
ducts can reduce energy loss and
inhibit mold growth. Fans installed with
existing ducts may not achieve their rated
airflow.
4-inch round rigid metal duct is recom-
mended for best performance.
Trusses
around
the
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. When installed in a wall or sloped ceiling, the duct connector must
point up.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information
and requirements.
5. The wearing of safety glasses and gloves is recommended when
installing, maintaining or cleaning the unit to reduce the risk of
injury that could be caused by the presence of thin metal and/or
high moving parts.
If this fan is to be used to ventilate a garage:
A. Use only in single family, residential garages
B. Install in a GFCI protected branch circuit
C. To help offset the risk posed by high concentrations of vapors
from paints, glues, solvents, and fuels, install fan at least 18
inches (0.5m) above the floor
D. NEVER run a vehicle or use a fuel burning appliance inside of
a garage. Deadly levels of carbon monoxide can build up in the
area. Using this garage fan, or opening windows and doors, will
NOT supply enough fresh air to eliminate the danger.
E. Run regularly if exposed to salty air environments
F. Extra cleaning may be required due to possible dirty surroundings
INSULATION*
(Place around and
over Fan Housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
Housing.
ROUND
DUCT*
Seal duct
joints with
*Purchase
tape.
separately.
CEILING INSTALLATION SHOWN
LP80 & LP110
NOT FOR USE IN A COOKING AREA
Do not install above or inside this area
45°
45°
Cooking
Equipment
Floor
OR
ROUND
ELBOWS*
Installation Guide
n
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in