2 PREPARING THE OPENING (Continued)
9/16"min.
flat
TheStandardInstallationofthisDrop-InRangeistohang
bythecountertoponthesidemetalflang e sunderglass
cooktop.This Range must not be installed on a base or
sub structure (2"x 4" support).
Iftheconstructionofyourcabinetcannotprovidea
1/4"flatareaatthebackofthecountertopopening,
considerchangingthecountertoptoaccommodatethis
dimension.Iftheareaisnotflat,excesstensionmay
beappliedtotheglasscooktop,causingbreakageand
voidingthewarranty.
• C ountertopthickness1-1/4"min.isrequiredtosupporttheproduct.Bracesmustbeinstalledbetweenthe
undersideofthecountertopandthecabinetifrequiredtoobtain1-1/4"minimumthickness(eachside).
• M akesurethewallcoverings,countersandcabinetsaroundtheovencanwithstandtheheat(upto200°F
(93.3°C)generatedbytheoven.
• T hisappliancehasbeenapprovedfor0"spacingtoadjacentsurfacesabovethecooktop.However,a6"
minimumspacingtosurfaceslessthan15"abovethecooktopandadjacentcabinetisrecommendedto
reduceexposuretosteam,greasesplatterandheat.
• L ocatethewiringjunctionboxattherearofthecutout.Thedimensionfromthetopofthewiringjunction
boxtothecountertopmustbeaminimumof28-1/2".Theboxmustnotextendmorethan3"offtheplane
ofthewall.Thejunctionboxmustbelocatedwhereitwillallowconsiderableslackintherangeconduit,so
thattherangecanbepulledoutforserviceifnecessary.
All manuals and user guides at all-guides.com
InstallationInstructions
1/4"min.flat
23-3/16"
29-15/16"–30-1/16"
smoothcut
Wall
25"
typically
9/16"min.
flat
3
Flat
area
R
1/4"
Rangesupport
Countertop