5.5 Configuration with DIP switches
Some settings can be changed with DIP switches
Procedure:
a) Turn the Compact on, preferably without load.
b) Set the dipswitches as required.
c) Store the settings by moving Dip switch 8 to "on" and back to "off".
5.5.1. DIP switch 1 and 2
ds1 (default setting "off").
If no panel connected: should be "off".
When connecting a Control panel: should be "on".
ds2: (default setting "on").
If no panel connected: should be "on".
When connecting a Control panel: should be "off".
ds5: Inverter frequency
ds6: Search Mode
5.5.2 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to 'off', except for DS-2).
DS-1 Panel option
DS-2 Panel option
DS-3 Not used
DS-4 Not used
DS-5 Frequency
DS-6 Search mode
DS-7 Not used
DS-8 Store setting
Example 1: (factory setting)
1
No panel connected
2
No panel connected
5
Frequency: 50Hz
6
Search mode off
8 store setting: off→ on→ off
Store the settings (DS3-DS7) by changing switch ds-8 from off to on, and then back to off.
The LED's 'Inverter' and 'eco mode' and 'alarm' will flash four times to indicate acceptance of
the settings.
12
off = 50Hz
off = off
off
DS-1
on
DS-2
DS-3
DS-4
DS-5
off
DS-6
DS-7
DS-8
→ ←
Example 2
1
2
5
6
8 store setting: off→ on→ off
on = 60Hz
on = on
off
on
off
off
→ ←
No panel connected
No panel connected
Frequency: 50Hz
Search mode off
DS-1
on
DS-2
off
DS-3
DS-4
DS-5
on
DS-6
on
DS-7
DS-8
→ ←
Example 3
1
Panel connected
2
Panel connected
5
Frequency: 60Hz
6
Search mode on
8 store setting: off→ on→ off