Cover the burner unit with the optional supplied protective cover when the
heater is not in use. Wait until the heater is cool before covering.
In a salt-air environment, such as near an ocean, corrosion occurs more quick-
ly than normal. Check frequently for corroded areas and repair them prompt-
ly.
TROUBLESHOOTING
Review these tips first and you may not need to call for service.
Problem
Pilot will not light
Pilot will not stay on
Burner will not light
Burner flame is low
Burner flame goes
off immediately
after ignition
Probable cause
Solution
Gas valve may be OFF
Turn the gas valve ON.
Tank fuel empty
Refill gas tank.
Pilot injector blocked
Clean or replace pilot injec-
tor.
Air in supply system
Purge air from lines by pres-
sing the control knob until
you smell gas.
Loose connections
Check all fittings.
Low gas pressure
Replace cylinder with a new
cylinder.
Battery is empty
Replace battery with a full
battery
Lack of fuel pressure
Keep the variable knob
depressed for 10-20 seconds
or more after the pilot light
ignited.
Tank near empty. Refill gas
tank.
Debris around pilot
Clean dirty area.
Loose connections
Tighten connections.
Thermocouple bad
Replace thermocouple.
Gas Ieak in Iine
Check connections.
Pressure is low
Tank near empty.Refill gas
tank.
Opening blocked
Remove and clean.
ControI is not 0N
Turn valve to ON.
Thermocouple bad
Replace thermocouple.
Pilot light assembly
Place pilot properly.
bent
Not in correct location Position properly and retry.
Supply hose is bent or
Straighten hose and per-
twisted
form leak teston hose.
Blockage in burner
Clean or replace burner
injector
injector.
Low gas pressure
Let the pilot flame stay lit
for 10 minutes before set-
ting variable knob to LO.