Electric Power Supply Requirements
Shortest connection from hard pipe stub
location to range hook-up.
Gas Supply
Installation must comply with local codes or, in the absence of local codes, with the National Fuel Gas Code,
Z21.1-2018
/ NFPA 54. In Canada, installation must conform to the current natural Gas Installation /code, CAN 1-1.1-M81
and with local codes where applicable.
This range has been design-certified according to
TYPE OF GAS:
NATURAL GAS
Supply Pressure
Minimum Supply Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Minimum Supply Pressure
Max Regulator Pressure
WARNING
Do not obstruct the flow of combustion air into the range and ventilation air away from the range
Ventilation: it is recommended that the unit be operated with an oven head, vented exhaust hood of sufficient size and
capacity.
Pressure regulator
Since service pressure may fluctuate with local demand, every gas cooking range must be equipped with a pressure
regulator on the incoming service line for safe and efficient operation.
The pressure regulator shipped with the range has female threads 1/2" NPT. The regulator shall be installed properly in
order to be accessible when the appliance is installed in its final position.
Area allows for flush installation with through-the-floor
connection of pipe stub/shut-off valve
ANSI STD Z21.1-2018
latest edition.
WC
4"
6"
14", 0.5 psi (3.5 kPa)
WC
10"
11"
14", 0.5 psi (3.5 kPa)
12
Area allows for flush installation
with through-the-wall connection
of pipe stub/shut-off valve and rear
wall 110/120V outlet.
ANSI STD