Descargar Imprimir esta página

Rocal HABIT 73 TC +T Manual De Caracteristicas, Instalacion Y Funcionamiento página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1. SPECIFICATIONS
1.1 Technical specifications
Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O
Average NO
concentration at 13% of O
x
Average OGC concentration at 13% of O
Particle concentration
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Outer fireplace safety distances
Outer fireplace safety distances
Outer fireplace safety distances
Fireplace room ventilation
Electrical wiring connection
Fan airflow (unit)
Fan output (unit)
Installed fans
Minimum safety distance to the air outlets
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate number
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Heat-resistant spray paint for touch-ups.
3. Fire grate.
4. Heat-resistant glove.
5. Cleaning cloth
6. Outdoor air intake Kit. (Outdoor air intake connector, support for the connector, tubular seal and screws)
7. Tool for handling registers and opening door.
8. Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
9. +T
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2. REQUIREMENTS PRIOR TO INSTALLATION
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This Flue liner should not be shared with other devices (see Table 1.1
2
2
2
(frontal)
(sides)
(back)
(entry - exit)
17/14327-852/853 M1
Habit 73 TC +T
11-13 Pa
2,8 kg/h
10,37 g/s
85%
11 kW
7,5– 13 kW
0,09%
3
71,5 mg/Nm
3
36,69 mg/Nm
38,69 mg/Nm
3
11,3 Pa
176 kg
3.5 kg
200 mm
450 mm
4000 mm
180 mm
100 mm
1000 mm
1000 mm
600 mm
450 cm
Silicone hose 3*wire of 1.5 mm
135 m
2
250 mm
178º C
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2017
Model
Habit 93 TC +T
3,56 kg/h
11,3 g/s
79,6%
12,4 kW
8.5 – 14,5 kW
0,085%
126 mg/Nm
48 mg/Nm
20,20 mg/Nm
12 Pa
197 kg
5 kg
200 mm
600 mm
180 mm
1000 mm
1000 mm
600 mm
2
2
3
/h
20 W
4
261ºC
2021
1880-CPR-024-21
3
3
3
11

Publicidad

loading

Este manual también es adecuado para:

Habit 93 tc +t