Descargar Imprimir esta página

KWC AQUA420 Instrucciones De Montaje Y Uso página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
8.
Dimensions
9.
Assembly
Warning!
Protect the power supply with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
If a faulty installation results in adjacent urinals interfering with each other, this can
be rectified by altering the sensitivity and by a selectable immunity mode
(see
Chapter
Take note of the flow direction.
9.1
Mount the water volume regulator (e) leak-tight.
9.2
Screw the solenoid valve (d) into the water volume regulator (e) so that it is leak-tight.
9.3
Secure the sensor (a) using the pre-installed hook strip on the siphon (b).
9.4
Connect the control unit (c) to the solenoid valve (d) and the sensor (a).
9.5
Connect the power pack (f) to the power supply (g, 230 V AC).
9.6
Check the function of the sensor (see
9.7
Disconnect the power pack (f) from the power supply (g, 230 V AC).
The piping between the urinal outlet and the siphon (b) must be provided by the
customer.
9.8
Connect the urinal outlet with the siphon (b).
9.9
Connect the solenoid valve (d) and the urinal with a hose.
9.10 Open the water volume regulator (e) using a hexagonal wrench.
h: closed
i: open
9.11 Install the urinal.
9.12 Connect the power pack (f) to the power supply (g, 230 V AC).
9.13 Pour at least 2 l of water into the urinal.
• Following the connection of the power supply, there is a lock time of 2 minutes.
• The system is now operational.
12.).
Chapter
10.).
- 6 -

Publicidad

loading

Este manual también es adecuado para:

2000071169