Descargar Imprimir esta página

Ravelli RBV 710 COMPACT Manual De Uso Y Mantenimiento página 50

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Rev.1 14/02/18
Pag.50
EN
If the floor that the stove is standing on is flammable, we recommend duly insulating it. Objects and parts that are heat-sensitive or
flammable cannot be stored near the stove; in any case keep these objects at a minimum frontal distance of 100 cm from the most
external point of the appliance's footprint.
Stove installation must guarantee easy access to clean the appliance, the exhaust ducts and the chimney.
To avoid overheating of the unit, air recirculation with one or more
openings must be created in the upper and lower part of the cladding
inside the fireplace structure covering the entire insert.
The following dimensions must be respected:
- bottom inlet for cold air drawn from the room, total minimum area
500 cm²
- top outlet for natural convection of hot air, total minimum area 450
cm².
The unit can be installed in an existing fireplace or in a special compartment built to measure and covered with plasterboard; in any
case the optional insert support can be requested.
If the compartment is accessible from the outside (a), position the insert with the base resting on the reference surface of the
compartment, pull out the monoblock, making sure it does not tip over, and secure the base with 8 anchors to the existing support
surface; if a support surface is not available (b), the height-adjustable insert support KIT, to be fixed to the floor, is available on request.
a
Use and maintenance manual RBV 710 COMPACT
Combustion air inlet
min. 100 cm²
Hot air OUTLET min. 450 cm²
Cold air INLET min.
500 cm²
b
Optional insert
support KIT

Publicidad

loading