Descargar Imprimir esta página

Ravelli RBV 710 COMPACT Manual De Uso Y Mantenimiento página 62

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Rev.1 14/02/18
Pag.62
EN
1
4
5
By pressing the Increment key you can change each value and, at step 3, enable the days of the week;
By pressing the Increment key you can change each value and, at step 3, enable the days of the week;
Press "confirm" to confirm the settings and switch to the next value;
Press the "back" button to return to the CHRONO-THERMOSTAT page.
As per the above example, it has been set as CHRONO 1 an ignition from 08.30 to 21.30 from MONDAY to FRIDAY at the
operating power 5 with a room temperature set at 21 ° C. Programmes 2-3-4 can be set in the same manner.
To exit the CHRONO-THERMOSTAT function and return to Stand-by page, press the button repeatedly.
AIR / PELLETS setting
Setting of the PELLET-FLOW mix enables you to immediately change the quantity of pellet loaded in the brazier and the air inflow.
The stove is tested and inspected with DIN PLUS certified pellets. If using another type of pellets or uncertified pellets, fuel may
need adjustment. Usually, the variation involves the FLOW percentage to adjust the input air and, therefore, the combustion; should
the regulation of flow be insufficient, it may be necessary to also change the percentage of PELLET load.
Below are given the steps for accessing the relative menu starting from Stand-By mode.
MENU
USER
MANUFACTURER
ENGINEER
Press the key "access
menu" to access
the
MENU page
As per the above example, you have set a percentage of -2 for PELLETS and +3 for the FLOW
that a setting like this is a consequence of the fact that the oxygen needed for combustion is insufficient and pellet
size is smaller than the average size of 2 cm.
To exit the SET AIR - PELLET function and return to Stand-by page, press the button repeatedly.
NOTE: The number indicated during the change of parameters refers only to a percentage value that acts on the default
parameters set on the electronic board (exclusively in the WORK phase). These values should be changed in the event
of poor combustion, due in many cases to the purchase of pellets differing from those used during stove testing.
Use and maintenance manual RBV 710 COMPACT
Press the key
"confirm"
to access the
USER page
Flow
Flow
2
1
Settable switch-on program
2
Settable switch-off program
3
3
Day of the week with active program
4
Number of "chrono" program (1-2-3-4)
6
5
Setting the power upon programming
6
Setting ambient temperature
USER
SCREW FEEDING
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
Flow
Flow
USER
SCREW FEEDING
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
Press the key
"selection"
to quickly switch to
SET AIR / PELLETS.
, an indication

Publicidad

loading