REPLACING THE e−CELL
Requires service kit AS20041 E−CELL
REPLACEMENT
Refer to the Wear Component Indicators panel on
the touch screen display for status of system wear
components. Order a replacement e−cell when
the remaining segment on the progress bar turns
yellow. Replace the e−cell when the the segment
turns red.
Order new e−cell
(yellow)
Replace e−cell
(red)
1. Disconnect power cord from outlet.
FOR SAFETY: When servicing machine
unplug cord from wall outlet.
2. Turn off water.
3.
Dispense either the MultiSurface or
MultiMicro solution into a bucket or a drain
to depressurize the system.
4. Remove front access panel using the access
key.
OS3 DM20036 (1−2018)
OPERATION EN
5. Disconnect ribbon cable.
6. Rotate retaining tab counter clockwise to
release the e−module. Loosen with a M7
wrench if needed.
7. With a firm grip pull out e−module from os3.
8. Flex tabs on manifold and separate from
e−cell. Dispose of old e−cell properly.
17