Descargar Imprimir esta página

Jocel JPEMGBG-654 Manual De Instrucciones página 29

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
• There is no spark when lighting
the gas
• The gas ring burns unevenly
INSTRUCTIONS FOR THE INSTALLER
Overall dimensions
Width: 640mm
Depth: 540mm
Cut out dimensions
Width: 560mm
Depth: 480mm
TECHNICAL DATA
Burner configuration
Triple Flame (Rapid)
Rapid burner (Medium)
Semi rapid burner (Medium)
Auxiliary burner (Small)
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
NG I
(20)
2H
Injector Dia.
(mm)
1.27
(314.5 L/h)
1.13
(257.3 L/h)
0.94
(166.8 L/h)
0.72
(95.3 L/h)
-27-
CORRECTIVE ACTION
LPG I
kW
Injector
Dia. (mm)
3.3
0.94
2.7
0.83
1.75
0.65
1.0
0.52
(28~30/37)
3+
kW
3.3
(239.7 g/h)
2.7
(195.6 g/h)
1.75
(127.1g/h)
1.0
(72.6 g/h)

Publicidad