Beninca HEADY 24 Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
The anti-crash device* (amperometric sensor) operation is adjusted in the open-
PMo2
ing phase, at normal speed - Motor 2.
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
PMc2
phase, at normal speed - Motor 2.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
Adjusts motor 1 speed during slowing phases. Value expressed in percentage of
SLD1
normal functioning speed.
Adjusts motor 2 speed during slowing phases. Value expressed in percentage of
SLD2
normal functioning speed.
The anti-crash device* (amperometric sensor) operation is adjusted in the open-
Pso1
ing phase, at reduced speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
Psc1
phase, at reduced speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the open-
Pso2
ing phase, at reduced speed - Motor 2.
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
Psc2
phase, at reduced speed - Motor 2.
The intervention threshold of the anti-crashing device (Encoder) during the phase
SeaU
at normal speed is adjusted.*
0:Off-1:minimum sensitivity - 99: maximum sensitivity
The intervention threshold of the anti-crashing device (Encoder) during braking
SEAR
is adjusted *.
0:Off-1:minimum sensitivity - 99: maximum sensitivity
* WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN AN HAZARD.
COMPLY WITH REGULATIONS IN FORCE!
With motors without limit switch and/or encoder it adjusts the sensitivity of the sensor which causes arrest during
slowing phase.
** 1: minimum force/torque - 99: maximum force/torque
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter
IbL
impulse has no effect during the opening phase.
Off: condominium function disabled.
Enables or disables rapid closing
On: rapid closure is enabled. With open gate, or in the opening phase, the
SCL
activation of the photocell causes the automatic closure 3sec after the total
opening of the gate. It is activated only with TCA:ON
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enables or disables the block function in opening.
On: Block function enabled. To use only with motors equipped with Limit
Blco
switch. After the intervention of the opening Limit switch the control unit delays
arrest by about 0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled
Enables or disables the block function in closing.
On: Block function enabled. To use only with motors equipped with Limit
Blc
switch. After the intervention of the opening Limit switch the control unit delays
arrest by about 0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled.
LOGIC (LOG)
FUNCTION
1-99-(50%)**
1-99-(50%)**
0-15-(2s)
0-40-(3s)
30-70 (40%)
30-70 (40%)
1-99-(20%)**
1-99-(20%)**
1-99-(20%)**
1-99-(20%)**
0-99-(0%)
0-99-(0%)
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
15

Publicidad

Tabla de contenido
loading

Productos relacionados para Beninca HEADY 24

Tabla de contenido