Beninca HEADY 24 Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Select the 1/2 motors operating mode:
1mot
On: Only motor 1 operating.
Off: Both motors operating.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Cvar
Off: Receiver enabled for rolling-code and programmable code transmitters
(self-learning and Dip Switch).
PP input as OPEN and PED input as CLOSED are enabled or disabled.
OPCL
On: PP input is enabled as OPEN and PED input is enabled as CLOSED.
Off: PP and PED inputs are enabled with their function.
Enables or disables the second radio channel on terminals 9/10.
2ch
On: Exit configured with function as second radio channel.
Off: Exit takes on function of service light (see Fig.3).
The service light function is enabled or disabled on the 9/10 output (see Fig.3).
On: This output has the function of service light. At each operation, the output
supplies 24VAC for around 60sec.
serl
The counting of the TLS time starts when the motor stops.
Use an auxiliary relay to control the light.
Off: The output features the SCA function, open gate light: light off with closed
gate, flashing light with moving gate, light on with open gate. See wire diagram.
The operating mode of input 13/18 (PHOTO) is selected.
On: Input for the connection of the mechanical safety edge (Normally Closed
(N..C.) contact), activated in both opening and closing phases. The activation of
the safety edge causes the gate stop and its movement reversion for around 3
seconds. The logics TST1 mush be OFF:
BAR
Off: Input for the connection of the photocell (N.C. contact), activated in both
opening and closing phases. When the photocell switches on (open contact), the
gate movement will stop. When the photocell switches off (closed contact), the
control unit will always send an opening control signal to the system, even if the
photocell was activated during closure.
Enables or disables checking of photocells on PHOTO input, active both in clos-
ing and in opening.
TST1
On: Check enabled. If the check has a negative result, no manoeuvre is com-
manded. See Fig.3 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables checking of photocells on PHOTC inputs, active only in clos-
ing.
TST2
On: Check enabled. If the check has a negative result, no manoeuvre is com-
manded. See Fig.3 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables motors check.
On: Check enabled. If the check has a negative result, no manoeuvre is com-
TSTm
manded.
Off: Check disabled.
(Enables or disables remote radiotransmitters learning, as indicated in the para-
graph "Remote transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
MENU
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
PP
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the second radio
channel.
2Ch
Press the key of the transmitter to assign to this function.
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the pedestrian
opening function.
ped
Press the key of the transmitter to assign to this function.
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
16
RADIO (RADi)
FUNZIONE
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)

Publicidad

Tabla de contenido
loading

Productos relacionados para Beninca HEADY 24

Tabla de contenido