NOTE!!!
The individual components of the gas control system should be installed in accordance with the re-
commendations of this manual.
The device can work only with the automation supplied with the device. The connections of the in-
dividual components of the system have been made in such a way as to prevent their improper con-
nection.
WARNING! The device is equipped with a highly sensitive tilt protection valve. Trembling of the
ground or the appliance itself due to impact or other forces may cut off the gas supply to the
appliance, thus shutting it down. If you notice that the appliance does not burn, immediately
turn the knob to the closed position clockwise and according to the instructions in the section
"firing up the appliance".
Sparkplug
Figure Wiring diagram of the GV32 manual gas control system.
42
Burner
controln
Thermoco-
uple
Interrupter block
Gas pressure regulator
Shut-off tilt valve
GV32 controller
Burner