Before replacing the cylinder, make sure that the device is not near sources of fire or other factors that
could catch fire. It is necessary to close the gas supply valve on the cylinder or regulator after each use.
If you feel a gas leak, you should absolutely stop using the device. If it is in operation I will turn it off, or
if it is turned off, do not start it. Then turn off the valve on the cylinder and contact the service center.
NOTE:
It is recommended to periodically check the quality of the connections of all gas connections, inclu-
ding the flexible rubber hose (at least once a month or whenever the cylinder is replaced). If there are
visible cracks, cuts or other signs of damage, the hose should be replaced with a new GOK hose, which
can be purchased from your dealer or kratki.com, or if this is not possible, ask your dealer, who will
recommend the model and type of hose appropriate for this appliance.
NOTE:
Note that the gas cylinder mounted inside the appliance must be attached by means of a string with
snap hooks inside the gas cylinder chamber to the structural components with holes.
GAS fLOW CONTROL OPERATING INSTRUCTIONS
The user of the PATIO SLC gas heater receives an appliance equipped with a GV32 control unit. Before
operating the control module, read these instructions. Proceeding contrary to the instructions or not
following the instructions may result in damage to the gas control system components or the applian-
ce itself, as well as cause fire, property damage or loss of health.
OPERATING INSTRUCTIONS fOR THE GV32 HANDHELD CONTROLLER MODULE
https://www.youtube.com/watch?v=zAH4mjTbsDg
Firing up the device should follow the instructions below. The GV32 gas control system is designed to
completely eliminate the need for maintenance and any adjustment. The knobs are non-removable.
Disassembly will result in damage to the appliance. Never attempt to tamper with the valve or any of
its structural components in any way.
firing up the device:
1. turn the "ON/OFF Knob A" knob slightly counterclockwise towards the IGNITION position until it
stops. Then press the knob in and hold it for 5 seconds (gas will flow only to the control burner).
(2) Continue to hold the knob down and at the same time continue to turn it towards the PILOT po-
sition (this activates the control burner piezo igniter). Hold the pressed knob in this position for
another 10 seconds until the control burner ignites (if the pilot does not ignite, repeat the procedure
immediately with the knob pressed at the same time).
(3) Once the pilot burner is lit, release the knob and turn it counterclockwise further to the ON position
(this will start the gas flow to the main burner as well).
Turning off the device:
1. turn the "ON/OF Knob A" clockwise until it stops at the PILOT position.
2. push the knob in slightly and continue turning it clockwise
from the PILOT position to the OFF position.
The re-ignition procedure of the control burner can be repeated when the thermocouple of the control
burner has cooled down sufficiently (the period to cool it down may vary depending on the type of
thermocouple used). After the device is completely turned off, re-ignition is possible after about 1
minute (the time required for the thermocouple to cool down).