LIST Of CONTROL ACTIVITIES
L.p.
Scope
General inspec-
1
tion
Windshield
2
control
Control of the gas
3
control system
Combustion
4
chamber
inspection
5
Elements
ENVIRONMENTAL PROTECTION
• Any packaging items in which the gas heater was delivered should be disposed of in a manner
appropriate to their type.e
• Due to their heavy metal content, batteries are classified as hazardous chemical waste, so after use,
they should be disposed of in special hazardous waste containers.
• If the operation of the device has come to an end, it must be disposed of. The user is obliged to
hand over the fireplace to an appropriate institution for the recycling of such devices.
48
Perform the firing procedure in the heater.
Check the correct operation of all safety systems. Check that the
flame of the main burner burns steadily.
Check that the main burner burns evenly.
Check that the batteries in the spark igniter do not need to be
replaced
Check the glass for cracks
Check the degree of dirt on the windshield. Clean the glass if
necessary.
Check the tightness of gas connections.
Check that the ventilation of the cylinder compartment is not
blocked
Check that the wires connecting the controller to the receiver are not
damaged. Check that the gas control system components are not
exposed to high temperatures.
Check that the inner chamber and the components installed in it are
not exposed to moisture. Check that the connecting wires do not
bear signs of corrosion.
Check that the thermocouple is within the range of the flame.
Check that the combustion chamber does not need cleaning.
Check that all air supply openings to the combustion chamber are
unobstructed. If necessary, unblock the openings.
Check the combustion chamber for signs of corrosion. If necessary,
remove the corrosion and cover the cavities with a new coat of
fireplace paint.
Check that the main burner ignites smoothly.
Check that the decorative elements do not need cleaning.
Check that the decorative elements are not in contact with the glass.
Check that the decorative elements do not obstruct the hearth air
holes.
Check that the decorative elements are not damaged.
Activities