Descargar Imprimir esta página

Porter Cable PXCM024-0275 Manual De Instrucciones página 4

Amoladora de troqueles en ángulo recto

Publicidad

Idiomas disponibles

Idiomas disponibles

Key Description
A
Air hose
B
In-line Filter
C
Tee Fitting
To begin using the tool:
1. As a standard practice, drain water from the air
compressor tank and air lines prior to use each day
(reference your compressor operators manual for detailed
instructions).
2. Install a 1/4" NPT male plug into the air inlet port on
the tool (see Figure B). Note: Use Teflon® Tape on all
threaded connections.
3. Turn on the air compressor and allow it to build up
pressure.
4. Adjust the air compressor's regulator or the supply line
regulator to 90 PSI.
Always make sure the tool is discon-
nected from any air supply before changing the grinding
stones or accessories, or serious injury could occur.
Grinders will attain extremely high R.P.M. or free speed. Use only accessories that are
rated with R.P.M. equal to or greater than the no-load free speed of your tool.
Inspect each grinding stone for cracks or chips prior to mounting. DO NOT use a grind-
ing stone that is chipped, cracked or damaged in any other way.
5. Select the desired grinding stone or accessory. NOTE: This tool is equipped with a 1/4" collet chuck,
which uses grinding stones and accessories with a 1/4" spindle.
To change the grinding stones or accessories:
a. Loosen the collet chuck with the collet wrenches (included with your
tool) by placing one collet wrench on the flats of the grinder shaft
to hold it from turning. Place the other collet wrench on the flats of
the collet chuck and turn counter-clockwise to loosen (see Figure
C).
b. Insert a grinding stone or accessory into the collet chuck, then turn
the collet chuck clockwise to tighten using the collet wrenches.
Make sure the grinding stone or accessory spindle is
fully inserted into the collet chuck opening and the collet chuck is
securely tightened. Loose attachments could fly off during operation
and cause serious injury.
c. After mounting a grinding stone or accessory, hold the grinder
under a workbench and run it for at least 60 seconds to be sure the
grinding accessory is secure. Make sure no one (including the
operator) is in the operating plane of the grinding accessory.
To change the collet chuck:
a. Loosen the collet chuck with the collet wrenches (included with your
TYPICAL INSTALLATION
Key Description
D
In-line Oiler
E
Air Hose
F
Whip Hose w/Swivel
OPERATING INSTRUCTIONS
Key Description
G
Quick Coupler
H
Male Plug
I
Air Tool
B
1
Grinder shaft
2
Trigger
3
Exhaust port
4
Teflon tape
4 - ENG
Key Description
J
Female Plug
K
Spray Gun
1
2
7
5
Male plug
6
Air inlet port
7
Collet chuck
C
To Tighten
A
3
6
4
5
To loosen

Publicidad