Descargar Imprimir esta página

Yokis MTR500M Manual Del Usuario página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Timing: The timing is deactivated by default. To change the value, see the corresponding section of the
MTR500.
Warning: See MTR500. The function is disabled by default.
Relay mode: In special cases, the dimmer light intensity variation function can be disabled and the product can
be turned into an electronic stepper relay. Press 20 times quickly (reply: 10 flashes). The product is set to work
as a dimmer by default.
Night courtesy light: press briefly 3 time to activate the night light for children: the brightness is set to 20%
and then decreases gradually over an hour. After one hour, the brightness is set to a minimum value (step
markers) for 12 hours.
Low light level setting:
- Adjust the desired minimum level by holding the pushbutton pressed.
- Then press shortly 27 times (reply: 7 flashes).
- Press shortly 28 times to restore the default minimum brightness level (reply: 8 flashes).
Configurations Lock/Unlock: The module is unlocked to allow configurations by default.
At the end of the configurations, to prevent any modification, the module can be locked by pressing briefly 21
times (reply: 1 flash). Press briefly 23 times to unlock at any time i (reply: 3 flashes).
All configurations are stored in the event of a blackout.
Presses *
Time
11
2 minutes
12
4 minutes
13
8 minutes
14
15 minutes
15
30 minutes
16
60 minutes (1 hour)
17
120 minutes (2 hours) 7 flash
18
240 minutes (4 hours) 8 flash
19
unlimited
Customer Service: +39 011.23.39.810 - Export Dept. Phone: +39 011.24.00.250/256
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from date of manufacture. The material must be used according to the
instructions provided and for its intended use. Faults must not be caused by deterioration or accidents resulting from negligence, anomalous use or incorrect installation. In
all cases, the warranty only includes replacement of faulty products. No compensation for loss or damage may be claimed.
DS1054-042C
Module configuration table
Reply
* SHORT PRESSES on the pushbutton (max. 0.8 second intervals)
1 flash
2 flash
The time is normally set in minutes (default) but may be
3 flash
set in seconds by means of a 25 presses sequence
(reply: 5 flashes). Press shortly 26 times to return to
4 flash
minutes (replay: 6 flashes).
5 flash
Example: To set a 15 second time:
6 flash
1 - Press shortly 25 times to select time in seconds
(reply: 5 flashes).
2 - Press shortly 14 times to select a time of 15 in
seconds (reply: 4 flashes)
9 flash
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
For technical information, go to www.yokis.com or call:
Fax: +39 011.24.00.296
P6
Time
Presses *
20
Soft Start ON/OFF (1)
Dimmer/relay mode (2)
21
Configuration lock
22
-
23
Configuration unlock
24
ON/OFF warning
25
Time in seconds
26
Time in minutes
27
Low light level setting
28
Reset minimum brightness
level (default)
29
ON/OFF Extended time (1)
Store/100% after first touch (2) 9 flashes
30
Default output reset
(1) For MTR500 and MTM500.
(2) For MTV500
Reply
10 flashes
1 flash
3 flash
4 flash
5 flash
6 flash
7 flash
8 flash
1 flash

Publicidad

loading

Este manual también es adecuado para:

Mtr500e54540505454060