Select the appropriate
battery type
Interpretation of the battery test results:
The battery is in good condition
The battery is no longer healthy and must
be replaced
Test Results:
(example values)
Volts:
Battery Rating:
Power available:
Internal Resistance:
LIFE:
Note for the internal resistance: On average normal range is between 2-4 mOhm to 10-15 mOhm to be considered good. Above these values a
battery is considered aged or sulphated. Motorcycle batteries may have a higher internal resistance and still be considered good due to their
lower CCA values. Please always refer to the values given by the battery manufacturer.
Select the test
measure according
to your battery
12.68V
Indicates the State of Charge [SOC] of the tested battery)
320 CCA
Indicates the battery capacity rated output
286 CCA
Indicates the actual power output.
9.45 mOhm
Indicates the internal resistance of the tested battery.
89 %
Indicates battery life expectancy [Health] in percentage.
If it falls below 50 %, the tester will indicate that the battery must be replaced.
Use the arrows to change the
value by
5 and
+/-
by
100
+/-
The battery is OK but needs to be recharged (State
of charge is low).
The battery needs to be recharged and tested again to
confirm the final results.
Press the print button on the
Tester to print the results.