Descargar Imprimir esta página

KEKAI KT0527 Manual De Instrucciones página 17

Publicidad

Idiomas disponibles

Idiomas disponibles

11. Connect the gas hose and regulator after that
connect the regulator to the gas cylinder.
WARNING! Ensure the hose does not contact
any high temperature surfaces, or it may melt
and leak causing a fire.
After the cylinder is placed inside the heater, secure
the cylinder with block belt tightly.
12. Leak Check.
WARNING!
of the gas system is replaced.
WARNING!
in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to
property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually,and whenever any gas Components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing
Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections
of the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended
by the Customer Care department and have the patio heater inspected by a certified gas installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it,and have the patio heater inspected
by a certified gas installer or dealer. Do not use the patio heater until the leak has been corrected.
A leak test must be performed annually and each time a cylinder is hooked up or if a part
Never use an open flame to check for gas leaks. Be certain no sparks or open flames are
Hose / Regulator
connection
Regulator / Cylinder
connection
11
12
- 13 -

Publicidad

loading