Humidity setting
Press the up or down button (b or c) to set the desired humidity
level in the room.
You can set the humidity from 30% to 90% at 5% intervals or "CO".
If the indoor humidity is higher than or equal to 3% or more of the
set humidity, the compressor and fan will run. The indicator light of
the compressor will be on.
After the humidity in the room is dehumidified, when the humidity
drops below 2% of the set humidity, the compressor is turned off
and the dehumidification is stopped. The indicator lamp (OK lamp)
that reaches the humidity is on.
If the dehumidifier stops dehumidifying and the humidity in the
room rises above or equal to 3% or more of the set humidity, if the
compressor has passed the three-minute protection status, the
compressor will start dehumidifying.
According to the above cycle operation, the indoor humidity can be
maintained at the set humidity.
The humidity indicator features 3 functions:
when you set the humidity, it will indicate the humidity that
-
you have selected.
when you program the time for the unit to turn on and off, it
-
will show the hours.
When the environment humidity is lower than 35%, it will
-
show "LO".
When the environment humidity is higher than 95%, it will
-
show "HI".
Water tank full:
If the water tank is full, its indicator will light on and the buzzer
sounds around 15 times. Press any key and the beep will stop.
At this time, the unit has stop running.
Press any key and the alarm will stop immediately.
Take out and pour water tank. Fig.2
10