The TSS system will work only when there's water in the
bucket or the base unit is connected with a water supply.
When there's no water connected with the unit, the On/Off
button has to be pressed to stop the unit.
m
IMPORTANT!
This system is capable of producing
8 Mpa. To avoid rupture and injury, do not operate this pump
with components rated less than 8 Mpa working pressure
(including but not limited to spray guns, hose, and hose
connections).
1. Open the battery compartment cover and slide the battery
in until it clicks to lock it into position, then close the
battery compartment cover (Fig. 16).
Fig. 16
Battery
compartment
cover
2. Remove the water bucket from the base unit and fill with
clean (fresh) water (Fig. 17).
Fig. 17
m
WARNING!
The intake water temperature must not
exceed 104ºF/40ºC.
m
CAUTION!
The washer must only be used with clean
(fresh) water; use of unfiltered water containing corrosive
chemicals will damage the washer.
m
WARNING!
Do not fill the bucket with the bucket still
fixed on the base unit.
3. Put the bucket back on the base unit. Make sure the
bucket is properly aligned on the base. Latch and lock
the buckles to ensure the bucket is securely connected
before using (Figs. 4 – 5).
NOTE: If you do not want to use the bucket, you can use
the base unit directly as a pressure washer. See following
instructions (step 4 – 5) to learn how to connect the base unit
with a water supply.
4. Connect the garden hose adapter (female coupler) to
the water inlet of the pressure washer on the base unit,
then thread your garden hose (male end) into the garden
hose adapter (Fig. 18). The garden hose must have an
internal diameter of at least 13 mm (1/2 in.) and must be
reinforced. The water supply must be at least equal to the
washer delivery capacity.
Fig. 18
Garden hose
Garden hose adapter
Water inlet
5. Attach garden hose to water supply (Fig. 19).
m
WARNING!
Water that has flowed through back flow
preventers is considered to be non-potable.
m
WARNING!
The water supply must not exceed 0.7Mpa.
12