4.3 ELECTRICAL CONNECTIONS ATTENTION
Electrical work to be carried out by a competent qualified and licensed
electricians in strict conformity to ruling national conditions and local
regulations. All wiring and external switchgear to comply with the ruling local
regulations in accordance with the latest edition of IEE wiring regulations.
Observe pump name plate data.
For pump fuse protection use a 3 Amp fuse.
A means of disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
The cable must not come in contact with the pump body or pipework.
WIRING PROCEDURE
If the pump already has a cable fitted to it, ensure the pump is isolated from
the mains before removing the terminal cover.
WARNING - 'THIS PUMP MUST BE EARTHED'
1. Use cable as recommended in secrion 1.2
2. Thread cable through grommet.
3. Depress levers to open cable clamps. Connect cable - Brown to L, Blue to N,
Yellow/Green to
(Fig 3a & 3b).
4 Adjust cable position and press outer sheath into clamp (Fig 3a).
5. Refit terminal cover, locating cover onto motor and tighten screw.
5