e
Connection to the air system
We recommend the use of air treatment units comprising lubrication, filtering and pressure
regulation on the air supply system.
Adjusting the setting force
WHEN IT IS DELIVERED, THE TOOL IS ALREADY SET TO THE MIMIMUM FORCE LEVEL.
IT WILL THEREFORE BE NECESSARY TO ADJUST THE TOOL WHEN FIRST USED.
EXCESSIVE SETTING FORCE CAN DAMAGE THE THREAD OF THE RIVKLE
PREVENT THE MANDREL FROM BEING WITHDRAWN FROM A SET RIVKLE
WHEN CORRECT SETTING IS OBTAINED, RAISE THE POSITION OF THE MULTICOLOURED
ADJUSTING RING AS A ROUGH GUIDE.
Figure 7 – Air connection
®
AND THE MANDREL OR
®
.