D- Setting/Using - SCS Sentinel OpenGate 3 MCO0063 Manual De Uso

Kit automatismos para puerta corredera - 24 volts
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

D- SETTING/USING

D1- Remote controls
To program a remote control : Press «RF-Learn» button for 2 seconds, and the LED display shows «CS». Then
push any button of the transmitter; the LED flashes twice and then be off. And the remote memory has completed
(picture 1,2 et 3)
LED2
Affichage
LED1
LED
viewer
1
2 Sec
You can now use your remote control as follow :
full opening
ON
OFF
release relay exit EXT+
EXT-
To cancel the remote controls memory :
Press and maintain the «RF-Learn» button until the LED display indicates
D2- System learning process, reset process and LED display
: The remote control memory storing operation must be over before starting the final system learning
process.
(1) To complete the system learning process, disengage your gate and remove it in the middle. Then re-engage
it again.
Step 1 : Press the button « SET », then « SET » + « DOWN » during 3 seconds, the LED display shows « LE » (Pictures
1,2 and 3, see following page)
Step 2 : Press the button on the top left of your remote control during 1 to 3 seconds, the LED display shows then
« LP » (Pictures 4 and 5)
Step 3 : The gate goes to auto-learning. It means it closes a first time then opens and closes again. Please wait
for the learning process to be completed.
LED
2
LED viewer
Affichage LED
clignote 2 fois
flashes twice
pedestrian opening
(approx. 10 s.).
LED screen turns
LED écran éteint
off