Lighting
Wood
3.3.3. Examples of air settings
Fig. 11. Lighting and reloading
3.3.4. Minimum air setting.
The adjustment knob for the minimum air intake can be found
underneath the stove, on the air flap assembly. It is factory set. This
knob allows you to increase, decrease or completely close the
permanent air intake.
Adjust this knob according to your chimney's draught, when the
chimney is at its operating temperature and using an accurate flue
draught gauge. See section 2.1.1, Chimney height requirements, for
the recommended flue draft.
Minimum air screw open
(this is the factory setting, suitable for a
normal flue draught).
Minimum air screw closed or nearly closed
(in the case of an excessively strong flue
Smokeless
Air Wash
Coal
draught)
Minimum
Fig. 12. Air wash.
Adjustment knob
10
Maximum (*)
(*) On certain models, press
the rotation stop button
inwards to enable the
maximum burn rate to be
achieved.
Fig. 13