Airfusion Climate Installation Instructions
Example: If a fan is connected to a circuit that can be isolated via an all-
pole safety switch at the switchboard, then this is considered to be an
all-pole disconnection to the ceiling fan electrical circuit, meeting the
requirements of clause 7.12.2 of AS/NZS 60335.1.
A single-pole switch on the active of the receiver input of remote
control must also be included in the wiring, and located the same
room as the ceiling fan.
5.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact
your local government for information regarding the collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain,
damaging your health and well-being.
6.
The structure to which the fan is to be mounted must be capable of supporting a weight of 30kg.
7.
The fan should be mounted so that the blades are at least 2.3 m above the floor in Europe or 2.1 m above the floor
in Australia.
8.
This fan is designed for indoor use only. Mounting the fan in a location where it is subject to water or moisture is
dangerous and will void the warranty.
9.
Only a licensed electrician should execute the installation.