7.
you can use tom to distribute scent in the room. we ask that you be ex-
tremely sparing with scents, as an excessively large dose can lead to
malfunctioning and damage to the appliance. to use scents, remove the
scent container (9) from the appliance and drip the scent directly into the
container. Put a maximum of 1-2 drops of the scent into the container.
Tip: if you would like to change the scent, remove the scent container
from the appliance, replace the absorbent cotton and clean the plastic
with soap. now tom is ready again to distribute another scent of your
choice in the room.
8.
as soon as the light "no water" lights up in red in the display (15), more
water must be added. For this, remove the water tank (2) and fill it with tap
water. after the tank is inserted, tom automatically resumes operation a
few seconds afterwards.
9.
if you would like to refill the water during operation, you can remove and
fill up the water tank. the appliance will continue to function for approx.
10-15 minutes with the remaining water. if you put the water tank back
in again during this period, tom can carry on functioning without inter-
ruption.
Cleaning
Before all maintenance and after every use, switch off the appliance and
remove the mains cable from the plug socket. Before you clean tom, the
mains cable (18) must be unplugged.
Attention: never dip the appliance in water (danger of short circuit).
For external cleaning, rub with a damp cloth and then dry thoroughly.
For internal cleaning, remove the lid to the water tank (1) and the water
tank (2). then loosen the magnetically attached front cover (16) on the
sides, using both hands, and place to one side. the water container and
the disc packet (12) can now be pulled out (grip on the underside of the
container).
Clean the water container (12) and the water tank (2) every
Clean the container thoroughly using a brush. if there are lime-scale de-
posits, the container should be soaked with decalcifier and then rinsed
thoroughly. in order to clean the water tank, rinse it out with hot water.
if lime-scale deposits can be seen, you can also de-scale the water tank.
rinse the water tank out with tap water and dry it afterwards.
Cleaning of the disc packet (10) approx. every
maining water from the water container (12). then pour in decalcifier (mix
ratio to water according to manufacturer's instructions) up to the upper
edge of the float in the container (12). seal the appliance again (tank must
not be inserted) and leave it running in "Clean" mode (see also point 6 in
setting up/operation) depending on the extent of the calcination.
Info: the ventilator does not run in "Clean" mode; only the disc packet (10)
is turned in the decalcifying fluid and thus ideally decalcified, without air
being blown into the room.
Ionic Silver Cube ™
the ionic silver cube (8) prevents the growth of germs and bacteria in the
humidifier due to the continuous release of silver ions. the use of an ionic
silver cube leads to a hygienic room climate. the lifetime of the ionic silver
cube is around one year. we therefore recommend that you replace the ionic
4 weeks: remove the re-
2 weeks.