Descargar Imprimir esta página

Hotpoint Ariston HNP 6.6 AM W/HA Instrucciones De Montaje página 35

Ocultar thumbs Ver también para HNP 6.6 AM W/HA:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Installation
of this manual.
Electrical hook up
The mains voltage must match that given on the ratings
label inside the hood itself. If the hood has a power plug,
connect the hood to an easily accessible regulatory power
socket. If it does not (direct connection to the mains), or the
socket is not easily accessible, install a two-pole regulatory
switch to enable total disconnection from the mains in case
of category III overvoltage, as required by the installation
regulations.
Caution! Always check that the mains cable is hooked
up properly and check that it operates correctly before
reconnecting the hood to the mains.
Air exhaust
(for ducted units)
Connect the hood to a duct and wall exhaust hole of a
diameter tube and exhaust hole reduces the extraction
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of
doing so.
! Use the shortest duct required to achieve the purpose.
! Use a duct with as few bends as possible
! Avoid suddenly changing the diameter of the duct.
! The duct must have as smooth an inner surface as
possible.
! The duct must be made of regulatory material.
!
fumes from other equipment (boilers, chimneys, stoves,
etc.).
! Observe the instructions of the competent authorities in
relation to the air exhaust. The air being exhausted may not
be exhausted into a wall cavity unless the cavity in question
! Equip the room with air intakes to prevent the hood creating
suction pressure in the interior (this must not exceed 0.04
mbar).
! The manufacturer is not liable for any consequences of
failure to observe these instructions.
Filter or ducted?
! Your hood is supplied as a ducted unit.
ACCESSORY KIT.
Note: If supplied with the hood, the accessory active
Instructions for transforming the hood from the ducted to the
Ducted version
Caution! The exhaust duct is not supplied and must be
purchased separately.
When routed horizontally, the tube must be angled slightly
upwards (around 10°) to enable the air to be conveyed
Filter version
version of the hood requires installation of an accessory
outlet slots uppermost.
Technical data
Height
Model
(cm)
PYRAMID 60cm
61-82
PYRAMID 70cm
61-82
PYRAMID 90cm
61-82
Model code
Bulb (V)
HNP 6.5 CM X/HA
HYM 60 IX/HA
HPM 61 IX/HA
7HHP 6 R (OW)/HA
Halogen
7HHP 6 R AN/HA
HRP 6.5 CM (OW)/HA
HRP 6.5 CM (AN)/HA
Model code
Bulb (V)
HNP 6.5S CD X/HA
HPS 60 IX/HA
Halogen
HRP 6.5S CM (OW)/HA
HRP 6.5S CM (AN)/HA
Model code
Bulb (V)
HNP 6.6 AM W/HA
HNP 9.6 AM W/HA
HNP 9.6 AM K/HA
HNP 9.6 AB X/HA
Halogen
HNP 9.6 AM X/HA
HNP 6.6 AM K/HA
HNP 6.6 AM X/HA
HRP 9.6 CM (OW)/HA
Halogen
Model code
Bulb (V)
HRP 9.8 CM (OW)/HA
Halogen
HRP 9.8 CM (AN)/HA
dia. of
Width
Depth
exhaust tube
(cm)
(cm)
(cm)
59.8
50
15/12
69.8
50
15/12
89.9
50
15/12
Bulb draw (W) Total draw (W)
2 x 25
160
Bulb draw (W) Total draw (W)
2 x 25
195
Bulb draw (W) Total draw (W)
2 x 20
210
2 x 25
220
Bulb draw (W) Total draw (W)
2 x 25
300
35
GB

Publicidad

loading