EN
and subsequently chilling cycles are not carried out correctly. For this reason, it is advisable to carry out
a defrost process from time to time, especially if several chilling cycles are performed consecutively.
In order to start a defrosting cycle, make sure that no other procedure is in use, open the door and press
UP/DEFROST
The duration of the defrost can be configured with parameters d3 and d7. Contact your
technical service for modification.
Compresor and evaporator fan status checking
In order to check the statur of the compressor, ensure ther eis no other cycle active. Press DOWN
Fig.5) button once and the status of the compressor will be displayed as follows:
•
"C-1", the compressor is switched-on
•
"C-0", the compressor is switched off
•
"C-P", compressor protection active (parameters C0, C1, C2 and i7).
To check the statur of evaporator fan, press
displayed as follows:
•
"F-1", the evaporator fan will be switched on
•
"F-0", the evaporator fan will be switched off
•
"F-P", then evaporator fan deferred activation will be ongoing (parameter F8).
To exit the procedure, Press
15 seconds.
Useful tips
Read carefully the below advices so as to reach the full potential of the refrigeration cabinet.
Maintenance
Carry out necessary cleaning operation in order to enlarge the service life of the machine.
•
Remove any waste from the machine at the end of each day. Before cleaning the machine,
unplug the machine from the electricity supply and put the switch in OFF or O position. The
appliances include a drainage in the bottom of refrigerated chamber (Except 3 trays models),
to help the cleaning operation, as well as the eventual output of liquids from food. During the
cleaning operation it is essential to remove the drain plug and clean it, to prevent clogging by
solid elements. It prevents accumulated liquids from stagnating.
•
Do not use abrasive, corrosive or acid products, chlorine-based detergents, solvents or petrol
derivatives to clean the machine.
•
Do not use pressurized water to clean the machine.
•
Take precautions before accessing to the unit condenser zone, due to the high temperatures
there might be risk of burns
•
Cleaning the condenser: During cleaning, avoid any bending of the condenser aluminum fins.
It could affect on the condenser air circulation, causing serious damage to the equipment,
being the repair out of warranty in that case.
•
Check that the doors close perfectly.
•
If any change of wires is needed, do not change for a lower section one
•
The assembly of the electrical installation cover in the control panel is important. If
disassembling is needed, it must be tightened back as it was.
•
Twice a year call the technical service to carry out the relevant revisions:
o
o
•
If the wire is damaged, it should be replaced by the manufacturer, its after sales service
department or by an autorized technicial to avoid any personal or equipment damage.
Prolonged non use
If the machine is kept out of service for a long period of time (holidays, temporary closure...), please
observe the following:
•
Clean the equipment carefully.
•
Switch off the mains power supply.
(11, Fig.5) button for 4 seconds.
SET
(14, Fig.5) button or do not take any further action for the following
Review of the status of the joints.
Review of the state of the components.
(12, Fig.5) button once again and the status of the fan will be
25