SPARK ARRESTER MAINTENANCE
If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding.
NOTICE
The spark arrester must be serviced every 100 hours to maintain its efficiency.
8. transport and storage
When transporting the generator, turn the engine switch and the fuel valve OFF. Keep the generator level to prevent fuel spillage.
Fuel vapor or spilled fuel may ignite.
warning
Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine cool before transporting or storing
the generator.
Take care not to drop or strike the generator when transporting. Do not place heavy objects on the generator.
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
storage time
Less than 1 month
1 to 2 months
2 months to 1 year
1 year or more
Contact your authorized generator dealer for conditioner recommendations.
RECOMMENDED SERVICE PROCEDURE TO PREVENT HARO STARTING
No preparation required
Fill with fresh gasoline and add gasoline conditioner*
Fill with fresh gasoline and add gasoline conditioner*
Drain the carburetor float bowl
Fill with fresh gasoline and add gasoline conditioner*
Remove the spark plug. Put a tablespoon of engine oil into the cylinder. Turn the engine
slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil.
After removal from storage, drain the stored gasoline into a suitable container, and fill with
fresh gasoline before starting.
*Use gasoline conditioners that are formulated to extend storage life.