QTREN SERIES
FAN / LIGHT / NIGHT LIGHTS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and stan-
dards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch cir-
cuit.
8. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch. Duct connector must point up. DO NOT MOUNT
THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
MODELS QTREN080FLT • QTREN110FLT
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If
the motor bearings are making excessive or unusual noises,
replace the motor with the exact service motor. The impeller
should also be replaced.
OPERATION
The fan, light, and night light can be operated separately. Use a
3-function wall control. Do not use a dimmer switch to operate
the light. See "Connect Wiring" for details.
WARRANTY
NUTONE THREE YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a
period of three years from the date of original purchase. THERE ARE NO
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FIT-
NESS FOR A PARTICULAR PURPOSE.
During this three-year period, NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal main-
tenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other
than by NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on
how long an implied warranty lasts, so the above limitation may not apply
to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE'S OP-
TION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REM-
EDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR
INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING
OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFOR-
MANCE. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify NuTone at the address
or telephone number stated below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evi-
dence of the original purchase date.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227
(1-800-543-8687)
Page 1

Publicidad

loading

Resumen de contenidos para NuTone QTREN Serie

  • Página 1 3. To avoid motor bearing damage and noisy and/or unbalanced To qualify for warranty service, you must (a) notify NuTone at the address impellers, keep drywall spray, construction dust, etc. off power or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or unit.
  • Página 2 MODELS QTREN080FLT • QTREN110FLT Page 2 TYPICAL INSTALLATIONS PLAN THE INSTALLATION ROOF CAP 4-IN. ROUND DUCT Housing mounted anywhere Housing mounted toI-joists. between I-joists using hanger bars. WALL 4-IN. ROUND Purchase ELBOW separately The unit will operate most quietly and efficiently when lo- cated where the shortest possible duct run and minimum number of elbows will be needed.
  • Página 3 MODELS QTREN080FLT • QTREN110FLT Page 3 1b.Mount housing anywhere between 2. Attach trusses, joists, or I-joists using hanger damper/duct bars. connector. Sliding hanger bars are provided to allow for accurate posi- Snap damper / tioning of housing anywhere between framing. They can be duct connector used on all types of framing (I-joist, standard joist, and truss onto housing.
  • Página 4 Page 4 INSTALL GRILLE SERVICE PARTS Replacement parts can 5. Finish ceiling. be ordered on our website. Please visit us Install ceiling material. Cut out around housing. at www.nutone.com 6. Attach grille to housing. Squeeze grille springs and insert them into...
  • Página 5 IDONEIDAD PARA UN PROPÓSITO PARTICULAR. ASHRAE) y las autoridades de los códigos locales. Durante este período de tres años, NuTone, a su criterio, reparará o reemplazará, 5. Al cortar o perforar a través de la pared o del cielo raso, no dañe el sin cargo alguno, cualquier pieza o producto que se encuentre defectuoso bajo cableado eléctrico ni otros servicios ocultos.
  • Página 6 MODELOS QTREN080FLT • QTREN110FLT Página 6 PLANIFICACIÓN DE LA INSTALACIONES TÍPICAS INSTALACIÓN TAPA DE TECHO * CONDUCTO REDONDO DE 4 PULG. Montaje de la cubierta en viguetas “I”. Montaje de la cubierta en cualquier parte entre las viguetas “I” por medio de barras de suspensión.
  • Página 7 MODELOS QTREN080FLT • QTREN110FLT Página 7 1b.Instale la cubierta en cualquier parte 2. Acople el entre las armaduras, viguetas o viguetas conector del “I” por medio de barras de suspensión. regulador de tiro/conducto. Se proporcionan barras de suspensión deslizantes para facilitar la colocación adecuada de la cubierta en cualquier parte entre la Conecte a presión el estructura.
  • Página 8 Las piezas de recambio se 5. Termine el cielo raso. pueden ahora pedir en nuestro Web site. Visítenos por favor en Instale el material del cielo raso. Recorte alrededor de la www.nutone.com cubierta. 6. Acople la rejilla a cubierta. Apriete los...

Este manual también es adecuado para:

Qtren080fltQtren110flt