BM 2610033452 02-14_MR23EVS 3/3/14 9:50 AM Page 13
FIG. 8
INSTALLING MOTOR IN PLUNGE BASE
1. Release the base clamp lever.
2. Line up the MOTOR-TO-BASE 5V
CONTROL CONNECTION TRACK with the
slot in the plunge motor carriage and slide
the motor all the way into the carriage.
3. Motor will first slide past the base's motor
release button catch.
4. Re-clamp the motor by pressing base
clamp lever into closed position.
REMOVING MOTOR FROM
PLUNGE BASE
4. Hold router in horizontal position, open
base clamp lever, and pull motor upwards
until it stops.
5. Press secondary motor-release button and
pull motor out of plunge motor carriage.
PLUNGE BASE DEPTH ADJUSTMENT
BASE PLUNGING ACTION
The MRP01 plunge feature simplifies depth
adjustments and will allow the cutting bit to
easily and accurately enter the workpiece.
To lower the router:
Push plunge lock lever to the left, apply
downward pressure until you reach desired
MRP01 Plunge Base Preparation
Release Base
Clamp Lever
Motor Release
Button
SLIDE MOTOR
IN B SE
depth, and release pressure on lever to lock
(Fig. 9).
The plunge lock lever is spring loaded and
returns automatically to the locked position.
To raise the router:
Push plunge lock lever to the left, release
pressure on router and the router will
automatically retract the bit from the workpiece.
It is advisable to retract the bit whenever it is
not engaged in workpiece.
FIG. 9
Plunge
Lock
Lever
-13-
Fine
djustment
Knob