Descargar Imprimir esta página

Dupla MARIN P 4 Manual De Instrucciones página 7

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
You can now use the  and  buttons as well as the  and  buttons to set the current time. By pressing the Menu
button you confirm your programming and go back to the basic function.
3. Manual operation of the individual pumps:
To check the function and to vent the hoses, the pumps can always be operated manually by simultaneously pressing the
 and  buttons.
Manu Mode:
1 2 3 4 5 6 7 8
By pressing the  and  buttons again you select the different pumps. Pressing and holding the Menu button will run
the selected pump for the length of time the Menu button is pressed. The lit LED next to the pump indicates that this pump
is currently active. By pressing the Esc button you go back to the basic function.
4. Programming the individual dosing pumps:
Every one of the four dosing pumps can be controlled separately. A total of eight* dosing pumps can be controlled.
*Only with additional module.
Note: the dosing volume of 1,000 ml for each dosing unit should not be exceeded because this significantly reduces the
pump's service life. Having delivered the maximum volume of 1,000, a delay of at least 30 min should be maintained before
the next dosing unit.
· minimum flow rate of 1 ml can be set
· recommended max. flow rate 9,999 ml / day
· adjustable dosing time
· 1 – 24 dosing units / day can be set
· Interval days 0 – 30 can be set
· Output: approx. 60 ml / min
Press the Menu button to access the programming level.
Set
DATE & Time
Set
Program <
The < symbol indicates which programming level you have currently selected. Use the  or  button to navigate between
the programming levels. Confirm Set Program by pressing the Menu button.
Select Pump-set:
1 2 3 4 5 6 7 8
You can now use the  and  buttons to select the pump to be programmed.
By pressing the Menu button again you confirm the selected pump and can use the  or  button to set the desired
number of dosing units per day (1 – 24).
P1 Time Per Day:
For: 01 (1 – 24)
P1 represents pump 1 to be programmed, P2 pump 2 etc. Pumps 5 – 8 can only be programmed if an additional module is
connected.
info@ dohse-aquaristik.de · www.dohse-aquaristik.de · www.dupla-marin.com
Pumps
7

Publicidad

loading

Este manual también es adecuado para:

81560