Adjustments
When changing the type of gas, always change the injectors (see instructions in the table on page 15).
CHANGING THE INJECTORS
On an installed appliance, before changing the injectors and making the new adjustments, close the valve on the
supply pipe or gas cylinder.
Perform the following operations:
Close the valve on the supply pipe or gas cylinder.
-
Turn the appliance over, remove the galvanised steel plate and unscrew the two screws fastening the
-
burner (see figure 3 on page 44).
Push the burner away from the valve.
-
Unscrew the injector with a size 10 wrench and its bracket with a size 13 wrench. Then take the
-
conversion set (set of injectors), as shown in the figure below.
Change the injector and its gasket, as per the instructions in the correspondence table of the different
-
types of supply (table page 15).
Return the burner to its initial position and then tighten the two screws to lock the burner.
-
Clean and tighten the appliance's protection. We recommend that you record the new configuration
-
on the appliance's information plate and delete the old one.
Place the changed injector in the conversion bag and store it carefully. Then refer to the start-up
-
procedure.
IDLE FLAME
When the appliances are set to Butane/Propane gas, the idle screw is turned as far to the right as possible.
When switching from Butane/Propane gas to natural gas, loosen this screw until you obtain a good idle flame
setting (loosen by no more than one turn). The idle flame is set properly when the flame is not extinguished when
passing quickly from the maximum to the minimum positions. The flame must be as low as possible.
Set the idle flame with the cooking plate installed and fastened:
1. Remove the lever by pulling it toward you.
- 19 -