Descargar Imprimir esta página

Lithonia Lighting BGR ALO SWW2 MVOLT PER Instrucciones De Instalación página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

CAUTION: WIRING AND FIXTURE OPERATION
Make sure power is turned off !
Note: This fi xture is intended for use with conduit connectors,
conduit and a properly installed and grounded UL wet location
listed junction box.
Ground fi xture
Use Wire Nut (F) to connect the (copper) house supply ground
wire & the (green) fi xture ground wire. Note: If house wiring does
not include a ground wire, consult your local electrical code for
approved grounding methods.
For proper connection, place wire nut over wires
and twist clockwise until tight.
Connect supply wires
Use Wire Nuts (F) to connect the black fi xture wire to the black
power supply wire and the white fi xture wire to the white (neutral)
supply wire.
Turn on electricity at fuse or circuit breaker box and verify
success of installation. Note: Test fi xture at night or block
Photocontrol.
Apply silicone caulking (not included) for moisture seal.
Figure C
LIGHT COLOR DIAL
BRIGHTNESS LEVEL SETTING
Preset to full brighness (9000LM) indicated by the larger sun icon.
If lower brightness is desired set dial to small sun icon.
LIGHT COLOR SETTING
Preset to COOL/4000K. Set dial to desired light color.
BRIGHTNESS DIAL
See Fig.C
See Fig. C
INSTALL DIFFUSER
If desired,
Align the keyholes along the diff user rim with the 3 screw heads
around the edge of the fi xture bottom, push up and rotate counter
clockwise to install. Tighten screws to secure.See Fig. D.
Figure D
G)
Trouble Shooting Guide
If this fi xture fails to operate properly, use the guide below to
diagnose and correct the problem.
Verify that power is turned on at switch and breaker
Verify that fi xture is wired properly
Verify that line voltage is correct.
Test if Photocontrol works properly
The photocontrol in this fi xture is designed to turn on fi xture
light at low light levels.
If light does not come on or stays on:
Test if Photocontrol works properly:
Cover Photocontrol - Light should come on.
Shine a fl ashlight into Photocontrol - Light should go off .
If fi xture cylcles on and off :
Light refl ecting back off any surrounding surfaces enters the
photocontol. To correct problem, reposition the fi xture or eliminate
refl ective surface.
If further technical assistance is required, contact: Technical
Support at: (800) 705-SERV
This LED light provides low maintenance service with no bulbs
to change. Clean surfaces with mild soap and water. Do not use
abrasive materials such as scouring pads or powders, steel wool
or abrasive paper.
WARNING: There are no user serviceable parts inside fi xture.
Contractor Resources
Check out helpful programs, tools, installation videos and
more!
page 4

Publicidad

loading

Productos relacionados para Lithonia Lighting BGR ALO SWW2 MVOLT PER