Connect the tube (12 mm internal diameter and not more than 1.5 m in length) to the outlet
connector and an external drain. Check: that the tube is secured and cannot slip off, and that the
drain is at a lower level than the connector.
Make sure that the drainage pipe is sloping and that it is not higher than the level of the connector
(see figure): otherwise the water will remain in the tank. Also check that the tube is not choked,
bent or clogged.
Warning: if you are not using the continuous drainage feature, remove the drainage pipe from the
outlet and insert the rubber cap in the connector.
CLEANING AND MAINTENANCE
Important: before performing routine cleaning, remove the plug from the mains.
 To clean the tank, use water with a regular dishwashing detergent, and wipe with a soft sponge (do
not use steel wool or abrasive products). Rinse and dry thoroughly. The water temperature should
not exceed 40 °C. It is important that the tank is washed well and immediately after use to avoid
the formation of bacteria or odours.
 Periodically check that the air filter (4) is clean and that it is not clogged
by lint or fluff. To remove the filter, press the tab (11) in and push the
filter upward, as shown. To remove dust, use a brush or a vacuum
cleaner, taking care not to damage any part. If the filter is very dirty,
wash it in warm water and rinse several times. The water temperature
should not exceed 40 °C. After washing, allow it to dry completely
before replacing it. Do not wash it in the dishwasher.
 Do not use the dehumidifier without a filter because it may fill with dirt and will thus not work its
best.
 The main unit and control panel must only be cleaned with a soft cloth that has been slightly
dampened either with just water and/or detergent. It cannot be washed in the dishwasher or even
under the running water: if the electrical parts (including cable and plug) get wet, dry them
thoroughly and completely before use.
 For long periods of time, you should stow the unit always the device upright, away from dust and
moisture; we recommend using the original packaging.
 R134A is a refrigerant that complies with the European regulations on ecology; however, we must
recommend that you avoid piercing the refrigeration circuit of the device. At the end of its life, the
product must not be disposed of with household waste; it must be taken to a special collection
centre.
Copies of the I/B. Please reproduce them without any
changes except under special instruction from Bimar
(Italy). The pages must be reproduced and folded in
order to obtain a booklet A5 (+/- 148.5 mm width x 210
mm height). When folding, make sure you keep the good
numbering when you turn the pages of the I/B. Don't
change the page numbering. Keep the language
integrity.
17
Assembly page 17/51

Publicidad

loading

Este manual también es adecuado para:

Deu311.euMddt.10dmn3.qa3