Descargar Imprimir esta página

Urmet alpha 1168 Serie Manual De Instalación página 11

Lector de llaves de proximidad

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Call module
B
8 cm long cord provided with modules Ref.
A
1168/xx.
13 cm long USB cord provided with modules
B
Ref. 1060/48.
CAPABILITIES
Permits timed opening (from 0 to 99 seconds)
when:
— a user proximity key is placed close to the front
panel;
— the door-release key in the entrance to the
building is pressed (in standalone mode only).
The two-color LED, if enabled, displays the
recognition of a proximity key approached to the
front by changing color (from red to green).
Each time the door is opened, the 3-digit display,
if enabled, shows the type of activation and the
number of the key that has caused this.
Function not available in Ipercom systems.
'nnn'
number of the user key;
internal entrance button;
key not recognized.
DS1168-008F
Ipercom
Alpha panel
STRUCTURE
1) 3-digit display;
2) Proximity key sensor;
3) Two colour LED (red/green);
4) Module connection cable connector (IN);
5) Module connection cable connector (OUT);
6) Configuration button;
7) Configuration dip switches used for:
1 indicating LED state
1168/45
(default enabled)
1168/45G
2 display state (default enabled)
ON
3 RS485 BUS: 2Voice - Ipercom
mode / standalone mode.
1
2
3
1168/45 - 1168/45G Default:
1168/45W
2Voice / Ipercom
ON
1168/45W Default: standalone
mode
1
2
3
8) Terminal board;
9) Jumper for power from 2Voice / Ipercom system
or local power supply (Local PS).
1168/45 - 1168/45G default: 2Voice/Ipercom
power supply
1168/45W default: local power supply (Local
PS)
DESCRIPTION OF TERMINALS
PS- Negative for door opener input relay
PS+ Positive for door opener input relay
-/~ Negative for local power
+/~ Positive for local power
N.O. Lock relay normally open contact
C
Lock relay common contact
N.C. Lock relay normally closed contact
11

Publicidad

loading

Este manual también es adecuado para:

Alpha 1168/45g