SETTING OF RELEASE OPEN TIME
When you access this menu, the display indicates
the currently set door release time (factory setting:
't00').
The door release time can be set between 0 and
99 seconds.
Move the MASTER key close to the panel and hold
it in position for at least 2 seconds. The LED display
shows:
The display increases the first bar by one unit at a
time every second in a cyclic way (from 0 to 9).
Remove the MASTER key when the digit to be set
is displayed.
Approach and remove the MASTER key so as to
also set the second digit. At this point, the display
will show:
where 'XY' is the new door release time set.
Approach the MASTER key again to make the
changes effective ("Sto" appears on the display to
indicate that it has been stored).
ADVANCED PROGRAMMING
FUNCTIONS
A number of particular functions, not generally
used, are described below.
DELETION OF AVAILABLE KEYS
To delete an available user key from the memory,
you can use a simpler procedure than that described
above for lost keys:
WARNING: the procedure must be performed with
one key at a time.
— using a MASTER key, access the deletion menu
with the following shown on the display:
— present the key to be deleted.
— if the key presented is effectively present in
the memory, the buzzer will emit three beeps
and the display will show the 'key number' for
approx. 7 seconds.
— when the key number is shown on the display,
present the MASTER key to confirm deletion.
14
'tXY'
To restore normal functioning, present a MASTER
key to the front panel.
ACCESS IN THE CASE OF
LOSS OF MASTER KEY/
STORAGE OF NEW MASTER
KEYS
It is always possible to access a device, even
without the MASTER keys, provided you have a
blank key, i.e. a key that has never been stored as
user key on that device.
Proceed as follows:
— open the frame, so as to access the rear
button.
— press the rear button briefly;
— wait until the following is displayed:
— press the rear button again briefly;
— present the blank key which will be stored as
MASTER key in addition to or in replacement of
(if 3 have already been stored) of the MASTER
keys present.
— present this new MASTER key for at least 7
seconds so as to restore normal functioning.
— use this new MASTER key to access the
device.
ACCESS PASSWORD
Access from the rear button can be protected using
a 3-digit password.
When a password is entered in the device, the rear
button can be accessed subsequently only re-
entering the password.
WARNING:
If all the MASTER keys of a device equipped
with password are lost and you have forgotten
the password, IT IS IMPOSSIBLE TO ACCESS
DEVICE PROGRAMMING. In this case, get in
touch with the URMET Technical Assistance
Center in the area directly which will eliminate
the password without deleting any of the user
keys.
The password can be set on any device without
password (therefore on any device that leaves the
factory). Once the password has been entered, it
cannot be modified.
It can be deleted only using the complete memory
reset procedure (see below): IT IS ADVISABLE
THEREFORE
TO
BEFORE STARTING TO STORE THE USER KEYS
SO THAT THIS CAN BE DELETED IN THE CASE
OF ERRORS DURING THE ENTRY PHASE.
ENTER
THE
PASSWORD
DS1168-008F