Problem
The capsule is not held in
the infusion group and falls
directly into the capsule
container (6)
After having inserted the
capsule in the infusion
group, you cannot close
the control lever (1)
The coffee dispensed
by the machine is cold
The capsule is not ejected
correctly
Drips coming out of the
spout (4) at the end of
dispensing
Coffee dispensing does
not stop even if you press
the dispensing button
(2-3)
The coffee dispensed has
an acid taste
Cause
Control lever (1) not
completely open
Capsule not aligned with the
infusion group
Capsule container (6) full
Faulty boiler
Capsule stuck in the infusion group
Capsule container (6) full
If the fault persists, apply to the service centre.
This is not a fault.
Faulty components
The machine has not been properly
rinsed after descaling
Use of expired capsules
Completely open the control lever (1) so that
the capsule support comes out of its housing;
recover the unused capsule from capsule
container (6) and insert it again. If the fault
persists, apply to the service centre.
Open the control lever (1) and again and
then close it completely. If the fault persists,
apply to the service centre.
Make sure that the capsule container drawer
(6) does not contain too many old capsules
and cannot take any more, then empty it.
Apply to service centre
Close the lever (1) and open it again slowly
Press the dispensing button (2), and
slowly open the control lever (1) while
the water is being dispensed.
Make sure that the capsule container drawer
(6) does not contain too many old capsules,
preventing ejection of the used capsule;
empty it.
It is normal for a few drips to come out
at the end of dispensing.
Take the plug out of the socket and apply
to the service centre.
Rinse the machine again
Check the capsule expiry date