2.8.
Socket and plug installation instructions
Once the installation on the wall has been completed, to connect the eProfessional to the
electric network, simply insert the plug into a suitable electrical socket. If not present, proceed
with the installation of the socket in proximity of eProfessional. For the installation, please refer
to the plug specific instructions.
ATTENTION: The plug must be connected directly to a power outlet, without
adapters and in compliance with local regulations relating to electrical systems.
The use of adapters or cable extension sets is not permitted.
In the presence of an incorrect electrical connection, the risk of damage to people
or property is particularly high if the car is left in charge for a long time in an
unattended place.
The socket shall be compliant with standard "IEC 60309-1 and IEC 60309-4"
Socket installation
The equipment must be powered by connecting the three-phase plug with a compliant
three-phase socket according to EN 60309-1 and EN 60309-2 standards.
The charger's electrical data, which should be referred to in order to determine the correct size of
the power supply system, are shown on the charger's identification label (see chapter 1.3.).
A socket (female connector) installed close to eProfessional is required, having the following
requirements:
Amperage
Polarity
Nominal Voltage
Frequency
Reference Standard
Poles reference
IP grade
Both wall-mounting and switchboard-mounting versions of the socket are acceptable.
32A
3P+N+PE
400 V
50 Hz
IEC 60309-1, IEC 60309-4
6h
IP55
19