12. Charger indicator
Indicator status
Red LED
Green LED
On
Off
On
Flashing
Off
On
Flashing
Off
Flashing
Flashing
Note: Under certain conditions, the charge control system might reduce the charging current for safety
reasons. Charging can take longer as the result.
This will happen in the following cases:
Exhaustive discharge of the battery pack
The temperature of the battery pack is not in the desired range (between approx. 10° and 40°C).
In this case, continue the charging until the battery pack is fully charged.
Anl_GC_LC_18_Li_SPK7.indb 31
Anl_GC_LC_18_Li_SPK7.indb 31
GB
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Charging
The charger is charging the battery pack in quick charge mode.
The battery pack is fully charged (charging completed)
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack. Take the battery pack out of the
charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature
(approx. 20° C) for one day .