Alarm zone (2)
6
12
1
2
13
JT JA
14
Single zone EOL
Zone state
Value
Tamper (short)
0 Ω
Normal
Rt
Alarm
Rt+Ra
Tamper (open)
P/N 146550999-1 • REV C • ISS 30APR12
Ra
4
JA
Alarm (1)
JT
Rt
Tamper (3)
5
3
4
5
6
7
8
SW1
Default
0 Ω
4.7 kΩ
9.4 kΩ
11
JT
SW1 - Generic settings
LED ON
Remote ON
Positive Polarity
Range
2
1
4
m
( 3 ft )
1
.
EN: Installation Sheet
Description
DD1012(-D) and DD1012PI are dual motion sensors. They
combine the patented PIR mirror optics technology with the
patented Range Controlled Radar technology.
The DD1012PI is designed to be immune up to certain size
and build of pets. Pets up to 18 kg (about 35 cm height)
normally do not cause any problems in standard application
unless they are able to move higher than 35 cm from the floor
in the detection field of view.
Installation guidelines
See Figure 1.
The detector is intended to be mounted on walls but can also
be mounted on ceilings by using a mounting bracket.
Use the following guidelines to determine the best location to
install the detector.
Mount the detector so the expected movement of an
intruder is across the detection pattern (see Figure 3).
Mount the detector at a stable surface at a height between
1.8 m and 3.0 m (5.9 and 9.8 ft.) from the floor.
Do not mount the detector within 0.5 m (1 ft. 8 in.) of
metallic objects or within 1.5 m (4 ft. 11 in.) of fluorescent
lights.
Do not place objects in front of the detector that may
prevent a clear line of sight.
Place detectors at least 6 m (19 ft. 8 in.) apart, and use
the short-range setting to avoid interference, when
mounting detectors face to face.
The dual technology processing of this detector is very
resistant to false alarm hazards. However, avoid potential
causes of instability, such as:
PIR hazards:
Direct sunlight on the detector
Heat sources within the detector field of view
JA
LED OFF
6
Remote OFF
5
Not used
4
Negative Polarity
3
2
2
2
2
1
1
1
1
12
m
6
m
9
m
(
40 .
ft )
(
20 .
ft )
(
30 .
ft )
3 / 36