otherwise the water may not be drained
properly.
WATER PUMP FUNCTION: (Fig 2.2)
If you do not want to empty the water tank
every time it gets full, you can connect the
drainage pipe provided to the drainage outlet
to drain the water.
The water pump drains to an overhead room
located at a maximum 3 meters up.
When the deshumidifier is on, press the
water pump button (17) to iniciate this
function. The pilot light comes on (21).
When the tank water is to be filled, the pump
water function is activated.
The water pump cycles for 2 minutes with
period of 1 minute between each cycle.
The water pipe must be kept smooth,
otherwise the water may not be drained
properly.
The end of the pipe cannot remain in water. It
is highly recommended to install it on a place
that allows the water to drain constantly.
ONCE THE APPLIANCE HAS BEEN USED:
Stop the appliance using the Power button.
Unplug the appliance from the mains.
Put the power cord back in the power cord
housing.
Clean the appliance.
CABLE COMPARTMENT:
This appliance has a power cord housing
situated on its posterior.
CARRY HANDLE/S AND CASTORS:
This appliance has two handles on the side
of the body, which facilitates comfortable
transport.
There are also four castors to facilitate the
transportation of the appliance and avoid
injuries.
SAFETY THERMAL PROTECTOR:
The appliance has a safety device, which
protects the appliance from overheating.
If the appliance turns itself off and does not
switch itself on again, disconnect it from the
mains supply, and wait for approximately 15
minutes before reconnecting. If the machine
does not start again seek authorised
technical assistance.
CLEANING
Disconnect the dehumidifier from the mains
and allow it to cool before undertaking any
cleaning task.
Clean the electrical equipment and the mains
connection with a damp cloth and dry. DO
NOT IMMERSE IN WATER OR ANY OTHER
LIQUID.
Clean the equipment with a damp cloth with
a few drops of washing-up liquid and then
dry.
Do not use solvents, or products with an
acid or base pH such as bleach, or abrasive
products, for cleaning the appliance.
Do not let water or any other liquid get into
the air vents to avoid damage to the inner
parts of the appliance.
Never submerge the appliance in water or
any other liquid or place it under running
water.
If the appliance is not in good condition
of cleanliness, its surface may degrade
and inexorably affect the duration of the
appliance's useful life and could become
unsafe to use.
Then dry all parts before its assembly and
storage.
CLEANING THE AIR FILTER (FIG 3)
Clean the air filters every 2 weeks. If the air
filter is blocked with dust, its effectiveness
will be reduced.
Open the inlet grill and washing the air filters
by submerging them carefully in warm water
with a neutral detergent, rinse them off and
let them dry completely in a shady place.