Washer
A water pump or magnetic valve can be
connected to the WASHER connection for
a washer.
The current for which the water
pump or magnetic valve are sui-
table must correspond to the
onboard current (12 or 24 V).
Rain sensors
Consult the manual provided with the rain
sensors to determine how to install them.
Safeguards
Each wiper motor is individually protected
by a fuse. The washer pump is also pro-
tected by a fuse.
These fuses are under the lid of the con-
troller unit (see diagram below on how to
remove lid).
See 'Technical data' for fuse values.

101002.01

Technical data

Current
12 or 24 V DC
Current received *): approx. 10 mA
Number of wipers: 5 max.
Maximum wiper motor output: 120 watts

Internal fuses

Wiper motors: 10 A (5 x)
Wiper pump or valve: 5 A (1 x)
Switches
Wiper switch:
Function: ON – OFF (1 x making contact)
Function switch:
Function: MOM – OFF – MOM
(2 x making contact, reverting to middle
position) + lamp
*) Note: Controller unit only, not including
current used by wiper motors.