Problems And Solutions - Keeper FOREST 10 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7 PROBLEMS AND SOLUTIONS

PROBLEM
The motor does not work and red
light signal is activated
No output pressure
The engine does not stop when you
release the handle
The engine works intermittently
with the lever open
The battery has little autonomy
Irregular spraying
Battery gets self-discharged
PROBABLE CAUSE
Low battery
Empty tank
Dirty tank lter ref 8702
Dirty pump head
Air in hydraulic circuit
Empty tank
Pressure switch incorrectly adjusted
Dirty pump head
Pressure switch damaged
Dirty tank lter ref 8702
Incorrect nozzles with low ow
dirty handle lters
Connections bad contact
Battery out of use. Ref. 9030
Spoiled charger ref. 9031
Dirty nozzle
Nozzle out of use
Shortcut between battery and electric
circuit
28
SOLUTION
Recharge battery
Fill tank
Clean lter
Clean pump head
Remove nozzle and take off air
Fill tank
Regulate switch
Clean pump head
Change pump head
Clean lter
Only recomended nozzles
Clean lters
Check connection,
charger and electric circuit.
Change the battery.
Change charger
Disassemble and clean the nozzle
Change the nozzle
Check battery and control unit

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido